PHAMP
SERIES
Send pH Electrode
Signal 1,000 Feet Over Ordinary, Wire and Connectors or Coaxial
Cable
Interface pH
Electrodes Directly with Inexpensive mV Meters and Recorders or
Sophisticated Process Controllers and Data Acquisition Systems
Extend Useful
Life of pH Electrodes
Available With/Without
Automatic Temperature Compensation
|
The NEWPORT®
PHAMP Series Preamps are unity gain preamplifiers which convert the
high impedance mV signal of a pH or ORP electrode to a low impedance signal
which can travel 1,000 feet over ordinary wire and connectors not only
to pH meters and controllers which are designed with high impedance input
circuitry, but also to Process Meters and Controllers such as the IDP
and INFP which can not otherwise register the high impedance signal. In
many applications the PHAMP series Preamps will also extend the useful
life of expensive pH electrodes, lowering the output impedance of an aging
electrode allowing it to continue providing a measurable signal.
The PHAMP-1 is powered by lithium batteries with an estimated life
of 5 years when used with high input impedance instruments. The electronics
are entirely encapsulated in an epoxy filled stainless steel enclosure.
The input and output connections are industry standard BNC. The output
can be split from coaxial to separated leads with the 3073 adapter.
The PHAMP-2 is a 10-40 volt dc powered preamp which can be powered
by the excitation of a process meter or the optional PSU-12V power supply.
The electrodes are entirely encapsulated in a compact epoxy filled enclosure
designed for easy mounting in a manufacturing process. The PHAMP-2 offers
redundant outputs from either a BNC connection, terminal strip or both
at the same time.
The PHAMP-3 is the same as the PHAMP-2 (above) with the added feature
of AUTOMATIC TEMPERATURE COMPENSATION. With the output of a PHAMP-3 automatically
compensated for temperature variations, it is possible to use an inexpensive
but sophisticated process meter or controller (such as the NEWPORT®
IDP, INFCP, INFP Series) to monitor and control pH in place of more expensive
dedicated pH meters. The Automatic Temperature Compensating element required
is a 1,000 Ohm RTD. (ATC is not used on ORP measurements.)
SPECIFICATIONS
- COMMON
Output Offset: 1 mV typical; 2 mV max. which corresponds to .033
pH
Input Impedance: 1013 Ohms
Output Impedance: 20K Ohms
Output Voltage: -2000 mV to +2000 mV
Operating Temperature: 0 to 60░C
PHAMP-1 Internal Battery Powered Model
Dimensions: 95.25 L x 17.8 cm D,(3.75" x 0.7")
Weight: 5.7 g, (2 oz.)
Battery Life: Approximately 5 Years
PHAMP-2, PHAMP-3 External
Powered Dual Output
Model Power: 10 to 40 Vdc
Dimensions: 38.1 H x 76.2 W x 38.1 mm D, (1.5" x 3" x 1.5")
To
Order (Specify
Model No.) Prices shown in U.S. Dollars
Model No.
|
Description
|
Price
|
|
pH Preamplifier, single output, battery powered |
$59
|
PHAMP-2
|
pH
Preamp, 10 to 40 Vdc powered |
$79
|
PHAMP-3
|
pH
Preamp, 10 to 40 Vdc, with Auto. Temp. Comp |
$129
|
Model No.
|
Description
|
Price
|
|
BNC to Banana Plug adaptor |
$15
|
|
BNC
(plug to plug) 3' extension cable |
$14
|
|
12
Volt dc power supply |
$15
|
Each
unit supplied with operatorÆs manual.
Ordering Example:
PHAMP-1, pH preamplifier
($59), 3073 to Banana
Plug adaptor ($15),
$59 + 15 = $74.
|